OXFORD COMPUTER TECH LIMITED: ALL ELECTRICAL AND ELECTRONICS AND TELECOMMUNICATION DEVICES, SALES, SERVICES, AND INSTALLATIONS +255655948888

OXFORD COMPUTER TECH LIMITED: ALL ELECTRICAL AND ELECTRONICS AND TELECOMMUNICATION DEVICES, SALES, SERVICES, AND INSTALLATIONS +255655948888

Thursday, April 19, 2012

Copiers

canon ir3100cn giving me error code E000020-01a9.

Hello luvmor. The code means the that when the copier tries to calibrate its colors (gradation) it cant get the yellow to calibrate.This almost certainly because the yellow drum has reached the end of its life.On this machine,it is not as simple to replace the drum unit as it could or should be.Newer machines are far easier to perform a drum replacement.I would have to recommend a trained technician to perform this procedure.

 this code is for the density of the yellow toner, most likley has a bad drum.

E070 Intermediate Transfer Belt/

Remove the ITB cleaning assembly and clean and adjust the cleaning blade side seals so that the seals touch the blade on both ends. Reinstall and perform an ITB cleaning to verify that the seals are cleaning properly. Replace the side cleaning seals if proper cleaning is not being performed (part number FL2-0084-000; Blade Sheet, front and FL2-0085-000; Blade Sheet, rear).

check belt/ static can build up and discharge to the ITB home sensor causing false read early faults.
Ensure the sensor is not contaminated or the patch dirty due to soiling. If everything looks clean you should clean the ground plates and replace the roller static charge plates. FC5-0365-000, FC5-0364-000 these parts can become contaminated and no longer provide the necessary grounding path.

check the two Roller Static Charge Plates
Replace or reform the two Roller Static Charge Plates listed below.

When facing the right side of the machine with the right door open, plate number FC5-0364-000 is located near the front side of the machine at the bottom of the front side of the ITB Assembly.
IMG_7341.jpg
Plate number FC5-0365-000 can be located on the rear side of the machine after the ITB Assembly is removed.
IMG_7342.jpg
Both plates are listed in the parts catalog on figure 102 items 25 and 26.

Canon IR3100cn Error Code e000004-001

with that low amt. of prints- i would check this first--
Check to see if MS 3 is fully actuated with right door opened.

Remove the 2 screws holding the metal switch actuating cover (fig 13 pg 2-14 in parts catalog)which is located behind the plastic inner cover-
SW3.JPG1.jpg
Also check if the front cover actuator has come into contact with and detached the front cover sensor PS22. The sensor can come in contact with the sensor mount, causing the 5V line to be shorted.
this can damage the sensor---------------------


When you remove the 2 screws and begin to move the metal cover you will notice the gear and spring mechanism will release MS3 actuating arm.
Re-position the metal cover, replace the screws, plastic cover and check that the mechanical operation of opening and closing the Right Door are now correct.

Check the door actuating switch MS3. If the switch is in the fully actuated state even with the right door open this code will been present.
Loosen or remove the 2 screws holding the metal switch actuating cover which is located behind the plastic inner cover , & repositioning the metal cover

E0700001 ITB HP detection error


HP of the ITB fails to be detected even
after the specific period of time.
Abnormality of the HP sensor,
Deviation of the belt from its position to
either edge, or soiling of the seal

Clean the HP detection seal, Clean/Replace the HP
sensor

ITB-HP Sensor (PS19): FH7-7630

Canon IR3100cn Error Code e000004-001

If you have more than 200 000 prints need to be replaced: Fixing assembly 230 V......... FM2-0174

Inspect thermistor and switch on FIXING UPPER FRAME ASSEMBLY

error code E000020-0081.

have repalced the 4 developers and the drum. I have cleaned the Patch read image sensor and the ATR sensor.