E070 Intermediate Transfer Belt/

Remove the ITB cleaning assembly and clean and adjust the cleaning blade side seals so that the seals touch the blade on both ends. Reinstall and perform an ITB cleaning to verify that the seals are cleaning properly. Replace the side cleaning seals if proper cleaning is not being performed (part number FL2-0084-000; Blade Sheet, front and FL2-0085-000; Blade Sheet, rear).

check belt/ static can build up and discharge to the ITB home sensor causing false read early faults.
Ensure the sensor is not contaminated or the patch dirty due to soiling. If everything looks clean you should clean the ground plates and replace the roller static charge plates. FC5-0365-000, FC5-0364-000 these parts can become contaminated and no longer provide the necessary grounding path.

check the two Roller Static Charge Plates
Replace or reform the two Roller Static Charge Plates listed below.

When facing the right side of the machine with the right door open, plate number FC5-0364-000 is located near the front side of the machine at the bottom of the front side of the ITB Assembly.
IMG_7341.jpg
Plate number FC5-0365-000 can be located on the rear side of the machine after the ITB Assembly is removed.
IMG_7342.jpg
Both plates are listed in the parts catalog on figure 102 items 25 and 26.